INDEPENDENT MACHINE RESEARCH
Skip to main content
Independent machine intelligence · Research before the decision
THE MACHINEBLUE BOOKFree machine reference

Control support

Is the control on that machine still supported?

A machine can run for decades, but its control decides how easy parts, repair and software help will be. This page lists what control makers have published about phasing out their hardware, with the date and a link to their own page.

How to read it. Siemens marks each part with a status: PM400 phase-out started, PM410 sold only as a spare part, PM490 discontinued and in its final support phase, PM500 end of lifecycle. A discontinued control still runs; it means parts come from stock, exchange units or repair shops, and a retrofit may be the long-term plan. Several makers publish only a general lifetime-support promise, listed here as a policy.

Before you buy a used machine, find the exact control model and part numbers on the cabinet labels, then check them here and with the maker. Add it to your decision workspace

Siemens

Control / partStatusSinceSourceLast read
SINUMERIK 802D slT/M pro panel (6FC5370-0AA00-3AA0)End of lifecyclePM500 · End Prod. Lifecycle · Successor 6FC5370-0AA00-3AA1 (fully compatible) — Phase-out announced 2012-03-06 · cancelled 2012-03-23 · discontinued 2022-10-01 · end of lifecycle 2024-09-302024-09-30Manufacturer pageOfficial2026-10-07
SINUMERIK 810CCU1 module (6FC5410-0AY01-0AA0)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5410-0AY03-1AA0 (partly compatible) — Phase-out announced 2003-10-01 · cancelled 2003-10-01 · discontinued 2017-09-302017-09-30Manufacturer pageOfficial2026-10-07
SINUMERIK 810D / 840DMMC103 (6FC5210-0DA20-2AA1)Discontinued, final support phasePM490 · Prod. Discont. · Long-life repair — Phase-out announced 2002-11-21 · cancelled 2004-09-30 · discontinued 2019-11-302019-11-30Manufacturer pageOfficial2026-10-07
SINUMERIK 810DECCU3 module (6FC5410-0AY03-0AA1)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5410-0AY03-0AA2 — Phase-out announced 2005-04-01 · cancelled 2005-07-27 · discontinued 2013-11-082013-11-08Manufacturer pageOfficial2026-10-07
SINUMERIK 828DPPU 260.2 vertical (6FC5370-6AA20-0AA0)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5370-6AA30-0AA0 — Phase-out announced 2014-10-01 · cancelled 2015-10-05 · discontinued 2026-09-302026-09-30Manufacturer pageOfficial2026-10-07
SINUMERIK 828D BasicPPU 240.3 vertical (6FC5370-4AA30-0AA0)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5370-4AA30-0AA1 — Phase-out announced 2016-12-14 · cancelled 2016-12-14 · discontinued 2024-10-012024-10-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840DPCU 50 1.2 GHz (6FC5210-0DF25-2AA0)Spare part only (cancelled)PM410 · Prod. Cancellation — Phase-out announced 2007-10-01 · cancelled 2008-10-012008-10-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840D powerlineNCU 572.5B (6FC5357-0BB25-0AB0)Spare part only (cancelled)PM410 · Prod. Cancellation — Phase-out announced 2012-09-30 · cancelled 2013-10-012013-10-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840D powerlineNCU box (6FC5247-0AA00-0AA3)Spare part only (cancelled)PM410 · Prod. Cancellation — Phase-out announced 2014-04-01 · cancelled 2015-04-012015-04-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840D powerlineNCU 573.3 (6FC5357-0BB33-0AE2)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5357-0BB33-0AE3 (not fully compatible) — Phase-out announced 2003-03-01 · cancelled 2004-03-08 · discontinued 2015-09-302015-09-30Manufacturer pageOfficial2026-10-07
SINUMERIK 840D powerlineNCU 572.5 (6FC5357-0BB25-0AA0)Discontinued, final support phasePM490 · Prod. Discont. · Successor 6FC5357-0BB25-0AB0 — Phase-out announced 2011-12-16 · cancelled 2011-12-16 · discontinued 2020-11-162020-11-16Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slPCU 50.3-P (6FC5210-0DF33-2AA0)Spare part only (cancelled)PM410 · Prod. Cancellation · Successor 6FC5210-0DF33-2AA1 · Spare parts only with return of the defective unit — Phase-out announced 2011-01-10 · cancelled 2011-01-102011-01-10Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slPCU 50.3-C (6FC5210-0DF31-2AA0)Spare part only (cancelled)PM410 · Prod. Cancellation · Successor 6FC5210-0DF31-2AA1 · Spare parts only with return of the defective unit — Phase-out announced 2011-01-11 · cancelled 2011-01-112011-01-11Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slPCU 50.3B-P (6FC5210-0DF33-2AB0)Spare part only (cancelled)PM410 · Prod. Cancellation · Spare parts only with return of the defective unit — Phase-out announced 2013-04-05 · cancelled 2014-04-012014-04-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slPCU 50.5-P (6FC5210-0DF53-3AA0)Spare part only (cancelled)PM410 · Prod. Cancellation — Phase-out announced 2018-12-02 · cancelled 2019-09-302019-09-30Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slTCU 30.3 (6FC5312-0DA00-1AA1)Spare part only (cancelled)PM410 · Prod. Cancellation · Available only as a spare part — Phase-out announced 2023-10-01 · cancelled 2025-10-012025-10-01Manufacturer pageOfficial2026-10-07
SINUMERIK 840D slNCU 720.3B PN (6FC5372-0AA30-0AB0)Spare part only (cancelled)PM410 · Prod. Cancellation · Available only as a spare part — Phase-out announced 2023-10-01 · cancelled 2025-10-012025-10-01Manufacturer pageOfficial2026-11-19
SINUMERIK 840D slNCU 710.3B / 720.3B / 730.3B PNService company reports transition to PM410 (spare part only); Siemens’ own page lists the NCU 720.3B PN as cancelled from 2025-10-012024-10-01Service company reportSecondary2026-11-22
SINUMERIK 840D slHMI hardware (OPs, MCPs, TCU 30.3, HT8)Service company reports discontinuation, spare part only2025-10-01Service company reportSecondary2026-11-22

Mitsubishi Electric

Control / partStatusSinceSourceLast read
Legacy CNC (M4000 to L1/M1)Service-ended model table (Japanese)Service ended (12 legacy models)2007–2014Manufacturer pageOfficial2026-11-22
M50 seriesCNC seriesDiscontinued1998Manufacturer pageOfficial2026-11-22
M60 seriesCNC seriesDiscontinued; repair while parts remain available2006Manufacturer pageOfficial2026-11-22

FANUC

Control / partStatusSinceSourceLast read
All FANUC CNCSupport policyLifetime support for products in use (no per-series end dates published)—FANUC America CNC parts and repair page (cited in text; FANUC America’s terms require permission to link)Policy2026-10-30 re-check pending
All FANUC productsSupport policyLifetime maintenance for as long as products are used—Support policyPolicy2026-11-22

HEIDENHAIN

Control / partStatusSinceSourceLast read
TNC controlsExchange-unit serviceExchange units listed as current or discontinued (no dated TNC lifecycle page found)—Support policyPolicy2026-11-22

Mazak

Control / partStatusSinceSourceLast read
Mazak machines incl. MazatrolParts policyLifetime parts support on every Mazak machine (no per-control dates published)—Support policyPolicy2026-11-22

Okuma

Control / partStatusSinceSourceLast read
Okuma machines incl. OSPParts policyZero-obsolescence parts policy (no per-control dates published)—Support policyPolicy2026-10-07 re-check pending

Re-read automatically from public pages; last update 2026-11-22. “Re-check pending” means the last read did not reach the page, so the earlier reading is shown. Service company reports are labeled and are not the manufacturer’s statement. Nothing here is a promise of parts or repair; confirm with the manufacturer.

Control family and generation pages, with manuals and how to identify a control at the machine: all control families · Haas Classic · Haas NGC. Haas publishes no end-of-support dates for its controls that MBB could find (checked 2026-11-19); those pages show what Haas does publish.

Control support questions

Built only from the dated rows above that cite the manufacturer’s own page. Service-company reports and general policies are not used here.

Is the SINUMERIK 802D sl still supported?

Siemens lists: T/M pro panel (6FC5370-0AA00-3AA0): End of lifecycle (since 2024-09-30). Source: the manufacturer’s own page, linked in the SINUMERIK 802D sl table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 810 still supported?

Siemens lists: CCU1 module (6FC5410-0AY01-0AA0): Discontinued, final support phase (since 2017-09-30). Source: the manufacturer’s own page, linked in the SINUMERIK 810 table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 810D / 840D still supported?

Siemens lists: MMC103 (6FC5210-0DA20-2AA1): Discontinued, final support phase (since 2019-11-30). Source: the manufacturer’s own page, linked in the SINUMERIK 810D / 840D table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 810DE still supported?

Siemens lists: CCU3 module (6FC5410-0AY03-0AA1): Discontinued, final support phase (since 2013-11-08). Source: the manufacturer’s own page, linked in the SINUMERIK 810DE table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 828D still supported?

Siemens lists: PPU 260.2 vertical (6FC5370-6AA20-0AA0): Discontinued, final support phase (since 2026-09-30). Source: the manufacturer’s own page, linked in the SINUMERIK 828D table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 828D Basic still supported?

Siemens lists: PPU 240.3 vertical (6FC5370-4AA30-0AA0): Discontinued, final support phase (since 2024-10-01). Source: the manufacturer’s own page, linked in the SINUMERIK 828D Basic table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 840D still supported?

Siemens lists: PCU 50 1.2 GHz (6FC5210-0DF25-2AA0): Spare part only (cancelled) (since 2008-10-01). Source: the manufacturer’s own page, linked in the SINUMERIK 840D table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 840D powerline still supported?

Siemens lists: NCU 572.5B (6FC5357-0BB25-0AB0): Spare part only (cancelled) (since 2013-10-01); NCU box (6FC5247-0AA00-0AA3): Spare part only (cancelled) (since 2015-04-01); NCU 573.3 (6FC5357-0BB33-0AE2): Discontinued, final support phase (since 2015-09-30); NCU 572.5 (6FC5357-0BB25-0AA0): Discontinued, final support phase (since 2020-11-16). Source: the manufacturer’s own page, linked in the SINUMERIK 840D powerline table row; last read 2026-10-07. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the SINUMERIK 840D sl still supported?

Siemens lists: PCU 50.3-P (6FC5210-0DF33-2AA0): Spare part only (cancelled) (since 2011-01-10); PCU 50.3-C (6FC5210-0DF31-2AA0): Spare part only (cancelled) (since 2011-01-11); PCU 50.3B-P (6FC5210-0DF33-2AB0): Spare part only (cancelled) (since 2014-04-01); PCU 50.5-P (6FC5210-0DF53-3AA0): Spare part only (cancelled) (since 2019-09-30); TCU 30.3 (6FC5312-0DA00-1AA1): Spare part only (cancelled) (since 2025-10-01); NCU 720.3B PN (6FC5372-0AA30-0AB0): Spare part only (cancelled) (since 2025-10-01). Source: the manufacturer’s own page, linked in the SINUMERIK 840D sl table row; last read 2026-11-19. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the Mitsubishi Electric Legacy CNC (M4000 to L1/M1) still supported?

Mitsubishi Electric lists: Service-ended model table (Japanese): Service ended (12 legacy models) (since 2007–2014). Source: the manufacturer’s own page, linked in the Legacy CNC (M4000 to L1/M1) table row; last read 2026-11-22. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the Mitsubishi Electric M50 series still supported?

Mitsubishi Electric lists: CNC series: Discontinued (since 1998). Source: the manufacturer’s own page, linked in the M50 series table row; last read 2026-11-22. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.

Is the Mitsubishi Electric M60 series still supported?

Mitsubishi Electric lists: CNC series: Discontinued; repair while parts remain available (since 2006). Source: the manufacturer’s own page, linked in the M60 series table row; last read 2026-11-22. A discontinued control still runs; parts come from stock, exchange units or repair shops, so confirm with the manufacturer.