The control can retire
before the machine does.
A machine can run for decades, but its control decides how easy parts, repairs and software help will be. Here is how to check a specific control and what the makers themselves publish.
The machine can be sound and the control still be the problem.
Castings, ways and spindles can outlast the electronics that run them. When a control's parts are discontinued, the machine still runs; what changes is where repairs come from. Parts then come from stock, exchange units or repair shops, and a control retrofit may become the long-term plan.
Some makers publish dates. Others publish a policy.
| Maker | What the maker publishes | Example from MBB's record | Last read |
|---|---|---|---|
| Siemens | A lifecycle status per part number: PM400 phase-out started, PM410 spare part only, PM490 discontinued and in final support, PM500 end of lifecycle | SINUMERIK 840D powerline NCU 572.5 (6FC5357-0BB25-0AA0): discontinued 2020-11-16; SINUMERIK 802D sl panel (6FC5370-0AA00-3AA0): end of lifecycle 2024-09-30 | 2026-10-07 |
| Mitsubishi Electric | Dated discontinuation per CNC series | M50 series: discontinued 1998. M60 series: discontinued 2006, repair while parts remain available | 2026-10-29 |
| FANUC | A support policy, not per-series dates | Lifetime support for products in use; no per-series end dates published | 2026-10-29 |
| HEIDENHAIN | Exchange units listed as current or discontinued | No dated TNC lifecycle page found | 2026-10-29 |
| Mazak | A parts policy, not per-control dates | Lifetime parts support on every Mazak machine, including Mazatrol | 2026-10-29 |
| Okuma | A parts policy, not per-control dates | Zero-obsolescence parts policy, including OSP | 2026-10-07, re-check pending |
Status entries come from MBB's control support record, which re-reads each maker's public page; the date in the Last read column is when that page was last read. Service-company reports on the record are labelled there as secondary and are not used above. Nothing here promises parts or repair; confirm with the manufacturer.
Read the cabinet, then check the record.
- Photograph the control's model plate and the part-number labels inside the cabinet: the NC unit, the panel or operator station and the drives.
- Look the part numbers up in MBB's control support record and on the maker's own page, which each row links.
- Look for the parameter backup, the exported alarm and error history with its date range, and the list of software options installed.
- Where the maker publishes only a policy, ask its service organisation in writing whether parts and repair are available for that exact control today.
Not a reason to walk away. A reason to plan.
A discontinued control is a planning item, not automatically a defect. Weigh how long you intend to run the machine, how much downtime the work can absorb, and whether a retrofit is realistic. MBB does not publish retrofit costs: they depend on the machine, the control chosen and the integrator, so get written quotes.
Related: Rebuild, recontrol or replace? and service, parts and warranty.
Control family and generation pages, with manuals and how to identify a control at the machine: all control families, Haas Classic, Haas NGC.
Where these facts come from.
- MBB control support record (/control-support/), with each manufacturer's own page linked per row, rows last read 2026-10-07 and 2026-10-29.
Last reviewed October 29, 2026.